Buy Analogue input module,IE8 mA IE8. Browse our Mfr. Part No. IE8; Brand Allen Bradley I/O,module,Flex User Manual. Legislation. (Cat. No. IE8 Series B). 4. 1. 3. 2. 5. 6. 7. Module Installation. This module mounts on a terminal base unit. 1. the module. Installation Instructions. User manual • Read online or download PDF • Rockwell Automation IE4XOE2,IE8,OE4,D FLEX I/O ANALOG MODULE User.

Author: Doukus Vujin
Country: Thailand
Language: English (Spanish)
Genre: Business
Published (Last): 1 November 2009
Pages: 405
PDF File Size: 19.90 Mb
ePub File Size: 4.83 Mb
ISBN: 764-6-40205-143-9
Downloads: 69062
Price: Free* [*Free Regsitration Required]
Uploader: Zolohn

Not used – set to 0.

Rockwell Automation 1794-IE4XOE2,1794-IE8,1794-OE4,D17946.5.2 FLEX I/O ANALOG MODULE User Manual

Other Comments Use back for more comments. The manual helps you install, program and troubleshoot your modules. Analog modules have 15 words assigned to them. Channel 5 analog data sign bit. The 4—20mA mode scales in the module and uses all 16 bits. Likewise, you can reduce the write words to 0, thus eliminating the configuration setting and unused words. If you do not, refer to the appropriate programming and operations manual before you attempt to program your modules.

Word 1 Publication 6. For example, for the 8 input analog module, you have 9 input words, and 6 output words.

At present, these consist of: We recommend you frequently backup your application programs on appropriate storage medium to avoid possible data loss. Check to make sure that the 16 pins manul the male connector on the adjacent device are straight and in line so that the mating female connector on this terminal base unit will mate correctly. Then it initiates a block transfer write to configure the module and send data val ues.

  COUNTERPOINT IN COMPOSITION SALZER SCHACHTER PDF

If using Series A modules, do not use configure select and full range bit settings of 0. This bit is set 1 when an error is detected in slot position 6. Use the following formula: Channel 7 analog data – 12 bit left justified two’s complement number; unused lower bits are zero; 4 20mA uses all 16 bits. Throughout this manual we make notes to alert you to possible injury to people or damage to equipment under specific circumstances. In addition, range selection bits have been revised to include an Off condition.

Use caution to make sure that the female flexbus connector does not strike any of the pins in the mating male connector.

Channel 1 analog data sign bit. Mount the mounting plate 1 for the adapter module using two 6 self-tapping screws 18 included for mounting up to 8 modules and the adapter.

The second compute instruction has a final destination of an integer location. Purpose of this Manual. Identifies information about practices or circumstances that can lead to personal injury or death, property damage or economic loss. These bits must be set to 1.

The module is configured using a group of data table words that are transferred to the module using a block transfer write instruction.

Rockwell is one of the world’s leading technology companies. For this example, N Our value-added services include: This bit is set to 1 when all bits in the configuration register write word 1 are 0 unconfigured state.

The software configurable features available are: We assume that you know how to do this in this manual. Safe State Value Selection. This bit is set to 1 when all bits in the configuration register write word 5 are 0 unconfigured state.

IE8 & OE4 User Manual_百度文库

These programs show you how to: Refer to Appendix C for a table of values for various current and voltage modes, and an example of scaling to engineering terms.

  LPADMIN BAD DEVICE-URI SCHEME CUPS PDF

Mapping Data for the Analog Modules. Repair and Exchange Services. Then it initiates a block transfer write to configure the module if the power up bit is set. Refer to range selection above.

Appendix C also includes an example of scaling. The block transfer data file stores data that you want transferred to your module when programming a block transfer write or from your module when programming a block transfer read. Position the keyswitch on the terminal base As described under: These bits control the safe state analog outputs – Bit 00 corresponds to output channel 0, and bit 01 corresponds to output channel 1.

Check Problem s Type: Channel 1 Safe State analog data sign bit. Channel 0 analog data – 12 bit left justified two’s complement number; unused lower bits are zero; 4 20mA uses all 16 bits.

If the adapter does not recognize your module after installation is completed, cycle power to the adapter. This module is designed so you can remove and insert it under backplane power. When set 1indicates either a broken or open input wire, or input current at or below 4mA.

If a negative number is given in two’s complement, its complement a positive number is found in the same way: This bit is set to 1 when all bits in the configuration register write word 6 are 0 unconfigured state. Technical Accuracy Describe Problem s: